In 430 people aged ≥16 after zone 1–2 finger flexor tendon repair (403 analysed), long, short and mini splints gave similar mean PRWHE scores over 52 weeks (24.5, 23.5, 22.4; no significant differences). Serious adverse events: 10–11% in each group.
RCTn = 430
Bamford et al. Comparative effectiveness of three splints for rehabilitation after finger flexor tendon repair (FIRST): randomised controlled trial