Systematic review of 50 studies (28 meta-analysed): the pooled mean operating room noise level was 70.7 dB(A) (95% CI 69.0-72.3), above the WHO recommended 35 dB; highest in otolaryngology (78.8) and orthopaedics (73.3).
Meta-analysisn = 50 studies
Dixon et al. Operating room noise levels in anaesthesia: a systematic review and meta-analysis