In 100 adults having major noncardiac surgery, Hypotension Prediction Index-guided treatment was not superior to a proactive MAP ≤73 mmHg target: median time-weighted average hypotension 0.07 vs 0.16 mmHg (P=0.119); secondary outcomes did not differ.
RCTn = 100
Wu et al. Hypotension Prediction Index versus High Mean Arterial Pressure Target for Preventing Intraoperative Hypotension: A Randomized Controlled Trial