Systematic review of 14 studies (16.7 million patients) in high-income countries: estimated overuse was 19% for carotid duplex, 46% venous duplex, 92% renal artery angioplasty and 72% IVC filters (low–moderate certainty); overuse was linked to higher costs.
Meta-analysisn = 16,706,904
Kirkham et al. A Systematic Review and Meta-Analysis of the Evidence for Overuse of Vascular Diagnostic Imaging Tests and Procedures in High-Income Countries