In 627 patients with peripheral lung lesions ≤30 mm on radial EBUS bronchoscopy, cryobiopsy gave higher histological diagnostic yield than conventional sampling (adjacent/eccentric: 77% vs 65%; overall: 83% vs 75%), with more moderate bleeding (38% vs 19%) and pneumothorax.
RCTn = 627
Matsumoto et al. Cryobiopsy versus conventional bronchoscopic sampling for peripheral pulmonary lesions (Cryo-RCT): an open-label, parallel-group, randomised trial