Secondary analysis of 60 adults with knee osteoarthritis given a brace in the PROP OA trial: hidden temperature sensors showed 58–60% met minimum brace use at 12 weeks vs 83% by self-report; agreement was low (kappa 0.35–0.36) and fell further by 26 weeks.
Secondary analysisn = 60
Callaghan et al. Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients