In 4824 analysed surveillance colonoscopies (of 5309 randomised) in a population screening programme, computer-aided detection did not improve adenoma detection rate vs standard high-definition colonoscopy (58.8% vs 57.4%; aRR 1.02, 95%CI 0.95-1.10).
RCTn = 5,309 colonoscopies
Codesido-Prado et al. Computer-aided detection in surveillance colonoscopy: a population-based randomized trial