Systematic review of 41 studies in kidney transplant recipients: low intrapatient variability in immunosuppressant trough levels was associated with lower acute rejection risk (RR 0.56), and high variability with graft loss (HR 2.42, 95% CI 1.70–3.46).
Meta-analysisn = 41 studies
Lattimore et al. Impact of Intrapatient Immunosuppression Variability in Renal Transplantation Outcomes: A Systematic Review and Meta-analysis