In 60 hypoxaemic patients on NIV after extubation (randomised oronasal vs full-face mask sessions), occlusion pressure was measurable in all and predicted oesophageal pressure swing well (AUC 0.98 and 0.97); ventilator P0.1 and plateau pressure were less reliable.
RCTn = 60
Murgolo et al. Airway occlusions to measure inspiratory effort, respiratory drive, and lung mechanics during noninvasive ventilation