In a cluster randomised study across 139 Veterans Health Administration facilities, CADe availability raised adenoma detection rate from 50.7% to 54.9% versus 51.8% to 51.1% at control sites (OR 1.22, 95% CI 1.15–1.28); no change in other lesions or withdrawal time.
RCTn = 334,200 colonoscopies
Dominitz et al. Impact of Availability of Computer-Aided Detection Devices on Adenoma Detection During Colonoscopy: A Cluster Randomized Study