Prespecified secondary analysis of the CIRCUIT trial in type 1 diabetes pregnancy: closed-loop users spent more time in pregnancy glucose range in the 24 h before birth than standard care (79.6% vs 64.8%; adjusted difference 13.2 points) and less time <70 mg/dL postpartum.
Secondary analysis
Donovan et al. Intrapartum and Early Postpartum Use of Automated Insulin Delivery in Type 1 Diabetes: A Prespecified Analysis of the CIRCUIT Randomized Controlled Trial