Noninferiority RCT in 64 participants with postpartum haemorrhage from uterine atony after vaginal delivery: 6 h of intrauterine balloon tamponade was noninferior to 18 h for blood loss (median 110 v 135 mL); secondary outcomes did not differ.
RCTn = 64
Larrea et al. Intrauterine Balloon Tamponade Duration for Postpartum Hemorrhage: A Randomized Controlled Trial