Non-inferiority RCT in 270 pregnant women at high risk of preeclampsia: remote vs clinic BP monitoring showed no difference in the perinatal composite (HR 1.0), with fewer antenatal attendances (median 14 vs 16) and hospital admissions (HR 0.54).
RCTn = 270
Rajkumar et al. A randomized controlled trial comparing remote blood pressure monitoring with office-based blood pressure monitoring for women at high risk of preeclampsia