In 26 NIV-naive adults with chronic hypercapnic respiratory failure, automatic iVAPS AE vs polysomnographic titration of fixed pressure showed no significant differences in PaCO2, nocturnal hypoventilation or sleep quality, but used higher pressures with lower comfort.
RCTn = 26
Matute-Villacís et al. Automatic alveolar ventilation-targeted NIV mode vs polysomnographic titration of fixed pressure in naive patients with chronic respiratory failure