Secondary analysis of FIXIT (254 adults, severe open tibial fractures): ring external vs internal fixation gave similar median pain intensity at 6 months but greater pain interference (6.0 vs 4.0); no differences at 12 months.
Secondary analysisn = 254
Shu et al. Pain Outcomes Following Modern External Ring Fixation Compared with Internal Fixation for Severe Open Tibial Fractures: A Secondary Analysis of a Prospective Randomized Trial (FIXIT)