In 400 patients aged ≥60 having lung cancer surgery, individualised vs fixed 5 cmH2O PEEP did not reduce postoperative pulmonary complications (28% vs 25%; RR 1.09, P=0.60), despite lower driving pressures and better intra-operative oxygenation.
RCTn = 400
Wang et al. Pulmonary complications with individualised vs. fixed positive end-expiratory pressure in older patients recovering from lung cancer surgery: a randomised trial