In 173 patients with HFrEF and LBBB, conduction system pacing failed non-inferiority and was inferior to biventricular pacing for a 12-month hierarchical composite (OR 2.36, P=.002), though direct costs were $7090 lower.
RCTn = 173
Zimerman et al. Conduction System vs Biventricular Pacing in Heart Failure: The PhysioSync-HF Randomized Clinical Trial