In 205 treatment-naive patients with obesity hypoventilation syndrome, auto-adjusted NIV was non-inferior to manually adjusted NIV for 12-month PaCO2 change (-9.2 vs -8.7 mm Hg; non-inferiority P=.01) and saved 1528 EUR per patient.
RCTn = 205
Sánchez-Quiroga et al. Effectiveness of automatically-adjusted vs manually-adjusted noninvasive ventilation in obesity hypoventilation syndrome: a randomized clinical trial