Systematic review of 3 RCTs (126 patients, 341 implants) of screw-retained implant bridges: intermediate abutments reduced marginal bone loss only at 36 months (MD -0.13 mm, 2 RCTs), not at 12 or 60 months, with lower probing depth and no difference in survival or complications.
Meta-analysisn = 126
Molinero-Mourelle et al. Does the use of intermediate abutments impact screw-retained implant-supported fixed partial prostheses outcomes? A systematic review and meta-analysis of randomized controlled trials