Meta-analysis of 12 studies (4721 patients): AI models classifying salivary gland tumours on ultrasound had sensitivity 0.91 and specificity 0.86 for benign vs malignant, and 0.81 and 0.88 for pleomorphic adenoma vs Warthin tumour.
Meta-analysisn = 4,721
Chau et al. Classification of Salivary Gland Tumors on Ultrasound Using Artificial Intelligence: A Systematic Review and Meta-Analysis