In 80 recipients of extended criteria or DCD donor kidneys, adding 2 h end-ischaemic normothermic to hypothermic machine perfusion did not improve immediate graft function (39% vs 49%; OR 0.68, P = .38), and no secondary outcome differed.
RCTn = 80
Slagter et al. Normothermic versus hypothermic machine perfusion in kidney transplantation: A randomized controlled trial