Meta-analysis of 20 RCTs in primary pterygium surgery: fibrin glue vs sutures for conjunctival autograft fixation was associated with lower recurrence (pooled OR 2.46), shorter operative time and less day-1 pain; graft retraction findings were inconsistent.
Meta-analysisn = 20 trials
Tsai et al. Fibrin Glue Versus Sutures for Securing Conjunctival Autograft in Primary Pterygium Surgery: A Systematic Review and Meta-Analysis