In 208 patients randomised during robotic partial nephrectomy (178 analysed), haemostatic agents did not reduce bleeding vs none: mean haemoglobin fall 1.8 vs 1.7 g/dL (P=.5); major bleeding complications 6.7% vs 4.5% (non-significant).
RCTn = 208
Lazarovich et al. Randomized, Prospective Evaluation of Hemostatic Agents in Robotic-Assisted Laparoscopic Partial Nephrectomy