In 122 patients with HF with reduced ejection fraction not on optimal therapy, a remote digital titration platform raised the HF optimal therapy score more than usual care at 90 days (change 1.72 vs 0.44; P<0.001).
RCTn = 122
DeVore et al. Digital Platform to Optimize Guideline-Directed Heart Failure Therapy: Results of the AIM-POWER Trial