In 360 ICU patients with mild-to-moderate hypomagnesaemia, enteral magnesium did not establish noninferiority to IV replacement: mean 24-h serum magnesium 0.80 vs 0.92 mmol/L (difference −0.12; inconclusive). Enteral cut cost, waste, CO2 footprint and IV fluid.
RCTn = 360
Nguyen et al. Enteral When Compared With IV Magnesium Replacement in the Critically Ill: A Noninferiority Randomized Clinical Trial